Questions about speed, RCF, capacity, rotors, adapters, sample type, and application fit.

How should centrifuge rotors be stored after use?

It is recommended to take out the rotor after each use, wipe it clean with sterile medical gauze, and place it upside down on a stable workbench. It is strictly prohibited to use sharp instruments to scratch the surface of the rotor.

View answer

Are the parameter changes during operation intuitive?

Very intuitive. Veyon 2104 G supports displaying the change curves of rotation speed, centrifugal force and temperature on the same screen. The curve graph can not only reflect the real-time status, but also show the dynamic relationship between various parameters, which greatly facilitates scientific researchers to accurately control the centrifugation process.

View answer

How to ensure the stability of the centrifuge when running large-volume samples?

Veyon 2105 adopts a patented triangular link motor fixation and three-stage shock absorption system structure. This technology can firmly fix the motor at the bottom, effectively offset the tiny vibrations during operation, ensure that the machine can still operate smoothly under high speed and large capacity load, protect experimental samples and reduce noise.

View answer

How to ensure the stability of the centrifuge when running large-volume samples?

Veyon 2105 adopts a patented triangular link motor fixation and three-stage shock absorption system structure. This technology can firmly fix the motor at the bottom, effectively offset the tiny vibrations during operation, ensure that the machine can still operate smoothly under high speed and large capacity load, protect experimental samples and reduce noise.

View answer

After being used at high frequency in the laboratory for a long time, is the cavity easily corroded by acid and alkali samples?

Won't. The centrifugal chamber of this equipment is made of high-quality stainless steel and is additionally coated with a special anti-corrosion coating. This design not only improves the mechanical strength of the centrifuge chamber, but also provides excellent resistance to chemical corrosion, making it durable and adaptable to harsh biochemical experimental environments.

View answer

If the sample is over-speeded or the machine is running unbalanced, is the equipment protected?

some. The whole machine is equipped with a complete safety protection system, including door cover locking protection, over-speed automatic shutdown, over-temperature protection and unbalanced self-checking functions. Once an abnormality is detected, the equipment will automatically sound an alarm and stop running to ensure the safety of the operator and the experimental environment.

View answer

How to ensure safety during large-volume centrifugation?

The equipment has multiple safety protections, including door cover locking protection, automatic imbalance detection, and overspeed and overtemperature alarms. In addition, the system will detect the motor status in real time. If abnormal operation occurs, a warning window will automatically pop up and the buttons will be blocked to prevent misoperation.

View answer

Can the data from centrifugation experiments be traced?

Can. This equipment has a built-in intelligent background system that can automatically record every centrifuge operation data. At the same time, the change curves of rotation speed, centrifugal force, etc. during operation can be displayed on the same screen, which greatly facilitates data recording and tracing by scientific researchers.

View answer

What is the after-sales guarantee policy for the equipment?

The full range of Veyon brand products are CE and ISO certified and undergo strict QC quality control before leaving the factory. For this model, we provide factory after-sales service with a two-year nationwide warranty for the entire machine to ensure the continuity and stability of scientific research work.

View answer

The laboratory is often exposed to corrosive organic solvents. Will the rotor and cavity of the equipment be damaged?

Won't. The drive head angle rotor of this equipment is made of aerospace-grade super alloy composite material, and the centrifugal chamber is made of stainless steel super composite alloy, both of which have permanent corrosion resistance. We promise that the rotor and centrifuge chamber are resistant to all corrosive organic solvents or samples and have a lifetime warranty.

View answer

If the rotor is unbalanced during the experiment, how can the equipment ensure safety?

Veyon 2417 G features automatic intelligent rotor identification and automatic unbalance detection. The system will monitor the operating status in real time. Once abnormal operation or imbalance of the motor is detected, a floating window warning will immediately pop up and the buttons will be blocked to prevent misoperation and ensure the safety of personnel and equipment.

View answer

The laboratory environment is harsh. Can the rotor and cavity of the equipment resist acid and alkali corrosion?

Can. The driving head angle rotor of this equipment is made of aerospace-grade super-strong alloy composite material, and the centrifugal chamber is made of stainless steel super-composite alloy material. These materials are extremely resistant to acids, alkalis and organic solvents. We promise that the rotor and centrifuge chamber will be permanently corrosion-resistant and have a lifetime warranty.

View answer

Can key data from centrifugation experiments be recorded by the system?

Can. This equipment has a built-in intelligent management system that will automatically record every centrifuge operation data in the background. Users can retrieve and view it at any time. In addition, the rotation speed, centrifugal force and temperature change curves during operation are displayed on the same screen, making it convenient for scientific researchers to directly record the experimental process.

View answer

The centrifuge generates a lot of heat when running at high speed. How to ensure the stability of large-capacity samples?

The equipment is designed with a special cavity circulation air duct system. This air duct allows air to circulate between the centrifuge chamber and the cover, forcing away the heat accumulated in the motor and chamber. This excellent heat dissipation can effectively prevent the impact of temperature rise on biologically active samples and improve the stability of the entire machine.

View answer

What safety protection does the equipment have if the sample is unbalanced or the motor operates abnormally?

The device has multiple intelligent protection functions. The system will detect the rotation speed in real time. Once abnormal operation is detected, a warning window will automatically pop up on the screen and all buttons will be blocked to prevent misoperation. At the same time, the whole machine is equipped with multiple automatic fault alarm functions such as door cover locking, overspeed, overtemperature and imbalance.

View answer

Does this machine support gradient centrifugation? Is the operation complicated?

The device supports gradient centrifugation up to 10 steps. Experimenters can enter the program mode and freely edit the rotation speed, time and temperature of each gradient within the operating range. Operated through a 7-inch high-definition touch screen, the interface is clear and intuitive, and even complex gradient settings can be completed quickly.

View answer

How can the experimental data recorded by the intelligent system assist me in scientific research recording?

The equipment background will automatically record detailed data of each operation. The most important thing is that it supports parameter curve display on the same screen. You can intuitively see the relationship between rotation speed, centrifugal force and temperature over time, which is very helpful for scientific research records that require precise control of the experimental process.

View answer

At such a high speed, how to prevent experimenters from misoperation?

The system has real-time detection function. Once the motor is running in an abnormal state, a floating warning window will immediately pop up on the screen and all buttons will be blocked to prevent misoperation from the system level. In addition, the whole machine is equipped with multiple automatic protection functions such as overspeed and imbalance to ensure safe use.

View answer

What is the surface hardness of the connection between the rotor and the bearing of this high-speed machine? Will it wear out?

The surface hardness of the centrifuge barrel of Veyon 2420 RG reaches above 2300HV and the smoothness is below 0.04. The drive head rotor is made of aerospace-grade super-strong alloy composite material. Its hardness and wear resistance far exceed that of conventional materials, ensuring that it remains as strong as ever at the limit speed of 21,000r/min.

View answer

Will the circuit board fail due to moisture when used in humid coastal areas or laboratories with large temperature differences?

The equipment is designed with environmental adaptability in mind. It adopts a unique octagonal cavity connection structure, and is equipped with an automatic ventilation circulation system outside the cavity. The most important thing is that all its internal circuit boards adopt a suspended design. This structure has excellent heat dissipation and moisture-proof effects, which significantly improves the high reliability of the whole machine.

View answer

If the floor-standing centrifuge is used on the first floor of the laboratory or in a humid environment for a long time, is the circuit system prone to failure due to moisture?

Won't. Veyon 2105 RG uses a unique circuit board suspension design. Coupled with the automatic ventilation circulation system outside the octagonal cavity, this structure can greatly isolate bottom moisture and provide excellent heat dissipation, ensuring that precision circuits still have extremely high stability and reliability in humid environments.

View answer

For large-capacity refrigerated centrifuges, the pre-cooling process is usually slow. How efficient is this machine?

Cools extremely quickly. This equipment is equipped with the industry-leading "miniature automatic constant temperature control system adjustment technology". At a room temperature of 25°C, it only takes less than 3 minutes to cool down to 4°C. This significantly reduces waiting times before experiments and is particularly suitable for bioactive samples that require rapid cryogenic processing.

View answer

There are many acid and alkaline chemical reagents in the laboratory. Are the shell and cavity of the machine corrosion-resistant?

Very corrosion resistant. The casing of Veyon 2105 RG is made of stainless steel and specially treated with high-gloss piano paint, and the centrifugal chamber is also coated with anti-corrosion coating. Both processes have passed the 100-hour intensive smoke test without damage. They not only have beautiful appearance, but also can resist the erosion of various acid and alkali gases for a long time.

View answer

How to record and analyze the dynamic relationship between rotation speed and temperature during centrifugation?

The 7-inch high-definition touch screen intelligent system equipped with the device supports curved same-screen display function. During operation, the change curves of rotation speed, centrifugal force and temperature will be generated in real time and displayed on the same screen, with a clear and intuitive relationship. At the same time, the system will automatically record each operation data, allowing you to view and record experimental parameters at any time.

View answer

After large-capacity operation, will the condensed water generated in the cavity cause bacterial growth or mechanical parts to rust?

You don't need to worry. This equipment uses high-quality copper pipes with full soldering technology in its design, and is equipped with a special automatic condensate drainage system. This system can effectively discharge the condensed water generated during operation and keep the cavity dry. In addition, we recommend keeping the door lid open for a period of time after the experiment to allow residual water vapor to further evaporate naturally.

View answer

Will frequently opening the door cover of a large-capacity refrigerated centrifuge during sampling seriously affect the life of the refrigeration system?

Won't. Veyon 6106 RG is equipped with an automatic start-stop system for refrigeration. The refrigeration system will automatically stop when the lid is opened and resume operation immediately after closing the lid. In addition, the equipment adopts micro-automatic constant temperature control system adjustment technology, which not only improves the cooling accuracy, but also effectively extends the service life of the compressor.

View answer

How to ensure the wear resistance and smoothness of the centrifuge barrel surface at a rotation speed of 6200r/min?

The surface technical performance of this model of centrifugal barrel is extremely high: the surface hardness reaches more than 2300HV and the smoothness is less than 0.04. This high-intensity surface treatment ensures that under long-term high-frequency high-speed rotation, the inside of the barrel remains smooth as before, and particles generated by wear will not pollute the centrifugal environment.

View answer

Why is Veyon 6921 RG specifically equipped with “dual heating” technology?

This is in response to extremely high-precision temperature control requirements. In addition to the powerful refrigeration of the imported variable frequency compressor, the dual heating control technology can work together with the refrigeration system to achieve a more accurate and faster temperature balance, ensuring that the experimental sample can still be strictly maintained at the preset temperature point (temperature control accuracy of ±1°C) under the condition of high-speed friction heat generation at 21200r/min.

View answer

For 220kg floor-standing heavy equipment, will it be dangerous if the rotor is not placed properly during the experiment?

Won't. The equipment has automatic rotor identification and unbalance automatic detection functions. Once improper installation of the rotor or imbalance of the sample is detected, the system will automatically limit the speed or shut down with an alarm. In addition, this model uses a special inner cavity protective cover and a high-reliability electromagnetic lock to provide double locking security from both physical and logical aspects.

View answer

How to deal with the condensation water generated in the freezing chamber after high load operation?

Veyon 6921 RG adopts the best freezing chamber connection technology and the best thermal insulation foaming technology, and is equipped with an automatic condensate drainage system. High-quality copper tubes with full soldering technology can effectively drain accumulated water and prevent water vapor from causing damage to the stainless steel anti-corrosion cavity and precision rotor.

View answer

The weight of the machine is very light. Will there be any displacement on the table when it is running at a top speed of 12,000RPM?

Not at all. Although the net weight of the entire machine is only about 1.2kg, its core components have undergone rigorous dynamic balance calibration. Combined with the solid base design and the smooth operation characteristics of the maintenance-free motor, it ensures that it remains motionless even at the highest speed, fully ensuring the safety of the experimental bench.

View answer

What practical significance does the real-time displayed "change curve" have for scientific research analysis?

During operation, the change curves of rotation speed, centrifugal force and temperature are displayed on the same screen, making the dynamic relationship between each parameter clear and intuitive. This not only facilitates scientific researchers to accurately monitor the entire centrifugation process, but also provides a reliable visual basis for later data analysis and experimental review.

View answer

How to retrieve and record experimental data to meet scientific research traceability requirements?

The system background will automatically record every operation data, and users can retrieve historical records on the 7-inch smart touch screen at any time. In addition, the system supports the same-screen display of rotation speed, centrifugal force, and temperature change curves, making it convenient for scientific researchers to intuitively record the changing relationship between parameters.

View answer

What are the highlights of this model’s operating interface and intelligent functions?

The 6106 G is equipped with an industry-leading 7-inch high-definition full touch screen intelligent system. The screen supports operation with gloves and provides a 5-year warranty. The system is powerful and supports up to 10-level gradient centrifugation editing, and can automatically record each operation data in the background. The rotation speed and centrifugal force change curves during operation can be intuitively displayed on the same screen, which facilitates scientific research recording and traceability.

View answer

How does the equipment ensure stability and low noise during the operation of large-capacity samples?

The equipment adopts the patented "triangular link motor fixation and three-stage shock absorption system structure" to firmly fix the motor at the best balance point at the bottom, ensuring that the motor can still run at high speed and smoothly under load. Combined with the customized three-stage buffer hydraulic rod design, the operating noise of the whole machine is controlled at ≤58dB, which is very suitable for quiet scientific research environments.

View answer

Is it easy to replace the rotor? Do I need to use a special wrench tool?

It is very easy to operate and does not require any wrenches or rotor removal tools. Thanks to the high-precision drive head design, the fit between the rotor and the shaft is extremely high, and the experimenter only needs to gently lift it by hand to complete the loading and unloading. In addition, the equipment has automatic intelligent identification of the rotor and unbalance detection functions, ensuring experimental safety from both the operation and hardware levels.

View answer

Does this refrigerated centrifuge cool down quickly? How accurate is the temperature control?

Its cooling performance is extremely good. The equipment adopts industry-leading "micro automatic constant temperature control system adjustment technology", which can cool the system extremely quickly, usually from room temperature 25℃ to 4℃ in less than 5 minutes. In addition, its temperature control accuracy is strictly controlled at ±0.8°C, effectively protecting temperature-sensitive biological samples.

View answer

How does the equipment maintain stability and reduce noise when operating at high loads?

The equipment has a built-in patented "bottom triangular link motor fixation and three-stage shock absorption system structure". This design fixes the motor at the optimal balance point, ensuring that the motor can still run at high speed and smoothly under load. With the customized three-level buffer door cover hydraulic rod, the operating noise of the whole machine is controlled at ≤60dB, providing a quiet working environment for the laboratory.

View answer

What protection designs does this equipment have for wet or chemically corrosive laboratory environments?

Veyon 6106 GR has multiple protections for durability: First, its circuit board adopts a fully suspended design, which has excellent moisture-proof effect. Secondly, the centrifugal chamber is made of high-quality stainless steel and coated with a special anti-corrosion coating, which can effectively resist the erosion of various organic solvents. In addition, the equipment is also equipped with an automatic condensation water drainage system to prevent water accumulation in the cavity.

View answer

How to retrieve experimental data, and does it support the traceability of scientific research records?

This model is equipped with a 7-inch high-definition full touch screen intelligent system, supports operation with gloves and provides a 5-year screen warranty. The system will automatically record every operation data in the background, and users can view the historical records at any time. At the same time, the rotation speed, centrifugal force, and temperature change curves during operation can be displayed intuitively on the same screen, which greatly facilitates scientific researchers for data analysis and experimental traceability.

View answer

What is the core separation performance of the Veyon 2415?

This model demonstrates excellent separation efficiency, with a maximum rotation speed of 15,000 r/min and a maximum centrifugal force of 15,000 × g. It can quickly process trace amounts of samples and meet the needs of high-frequency experiments such as molecular biology and proteomics.

View answer

Does the smart touch screen of this centrifuge support operation with gloves?

Can. This model is equipped with an industry-leading 7-inch high-definition full touch screen "smart system" that not only has a clear display interface (simultaneously displaying speed, centrifugal force, time, temperature control and rotor specifications), but also supports experimenters wearing laboratory gloves for direct operation, and provides a 5-year screen warranty.

View answer

How to achieve accurate recording and scientific research traceability of experimental data?

The system background will automatically record each operation data, and users can view the historical records at any time. In addition, the system supports the same-screen display of rotation speed, centrifugal force, and temperature change curves. The change relationships are intuitive and transparent, which greatly facilitates scientific researchers to collect accurate data on the centrifugation process.

View answer

There is chemical corrosion in the laboratory environment. Is the durability of the equipment guaranteed?

Very secure. The driving head angle rotor of this series of models is made of aerospace-grade super alloy composite material, and the centrifugal chamber is made of stainless steel super composite alloy material and is plated with a special anti-corrosion coating. These core components are permanently resistant to all corrosive organic solvents, and manufacturers often offer lifetime warranties.

View answer

Is the equipment stable and quiet when running at high speed?

Yes. The equipment adopts a patented "triangular link motor fixation and three-stage shock absorption system structure" to firmly fix the motor at the bottom balance point to ensure that it remains extremely stable even under high-speed operation. The operating noise of the whole machine is controlled at ≤55dB, providing a quiet working environment for the laboratory

View answer